Anemómetro FLIR EM54, medición de Caudal de aire, Temperatura del aire, Velocidad de aire, Punto de rocío, Humedad
- Código RS:
- 185-3517
- Nº ref. fabric.:
- EM54
- Fabricante:
- FLIR
2 Disponible para entrega en 24/48 horas
3 Disponible para entrega en 24/48 horas
Añadido
Precio Unidad
269,00 €
(exc. IVA)
325,49 €
(inc.IVA)
Unidades | Por unidad |
1 + | 269,00 € |
- Código RS:
- 185-3517
- Nº ref. fabric.:
- EM54
- Fabricante:
- FLIR
Documentación Técnica
Legislación y Conformidad
- COO (País de Origen):
- CN
Datos del Producto
FLIR Ultrasonic Leak Detector, Air Flow Measurement - EM54
This ultrasonic leak detector by FLIR is a powerful tool designed to identify pressurised leaks in compressed air systems with high accuracy. The device is equipped with features such as air flow measurement and a vane probe for precise detection. The FLIR ultrasonic leak detector is ideal for professionals in the automation, electronics, electrical, and mechanical industries, offering an efficient solution to pinpoint efficiency loss and potential failures quickly.
Features & Benefits
• It provides high accuracy air velocity detection, ensuring reliable results
• With the ability to measure dew point, this leak detector offers comprehensive data for maintenance professionals
• Powered by a 9V battery, the FLIR ultrasonic leak detector is lightweight and convenient for on-the-go usage
• Equipped with a vane probe, this detector can effectively identify leaks in industrial environments
• The device offers ±2 °C temperature measurement accuracy, ensuring precise results every time
• With the ability to measure dew point, this leak detector offers comprehensive data for maintenance professionals
• Powered by a 9V battery, the FLIR ultrasonic leak detector is lightweight and convenient for on-the-go usage
• Equipped with a vane probe, this detector can effectively identify leaks in industrial environments
• The device offers ±2 °C temperature measurement accuracy, ensuring precise results every time
Applications
• Industrial leak detection
• Maintenance of compressed air systems
• HVAC system troubleshooting
• Equipment efficiency monitoring
• Maintenance of compressed air systems
• HVAC system troubleshooting
• Equipment efficiency monitoring
The FLIR EM54 is ideal for inspecting and troubleshooting HVAC/R ducting systems within residential, commercial, and industrial facilities. This meter can help you verify that duct inlets and outlets have the specified volumetric flow – a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, the EM54 can measure deviations from proper relative humidity levels. Plus, the included Type-K contact temperature probe is useful to check electric motors and thermal equipment components for proper operating temperatures.
Can it accurately measure air flow rates?
ACCURATE AND RELIABLE
Receive high-quality data consistently, and work without interruption. Using the tripod, place the meter away from objects that may influence relative humidity measurements.
INSPECT AND TROUBLESHOOT EFFICIENTLY
Work on a wide range of systems more efficiently using the contact temperature probe and wet bulb/dew point calculations.
EASY TO USE
Intuitively operate this simple, ergonomic meter with a backlit display, a hold function that freezes readings, and well-marked function keys.
Receive high-quality data consistently, and work without interruption. Using the tripod, place the meter away from objects that may influence relative humidity measurements.
INSPECT AND TROUBLESHOOT EFFICIENTLY
Work on a wide range of systems more efficiently using the contact temperature probe and wet bulb/dew point calculations.
EASY TO USE
Intuitively operate this simple, ergonomic meter with a backlit display, a hold function that freezes readings, and well-marked function keys.
Yes, it is capable of accurately measuring air flow rates, making it a valuable tool for maintenance professionals.
Will it help identify pressurised leaks in compressed air systems quickly?
Yes, the device is designed to efficiently pinpoint pressurised leaks in compressed air systems and offer fast solutions for maintenance issues.
Is it suitable for professionals in the automation industry?
Yes, the FLIR ultrasonic leak detector is ideal for professionals in the automation industry, providing a reliable solution for identifying leaks and efficiency loss quickly.
Especificaciones
Atributo | Valor |
---|---|
Parámetros de Medición | Caudal de aire, Temperatura del aire, Velocidad de aire, Punto de rocío, Humedad relativa |
Número de Modelo p | EM54 |
Velocidad Máxima del Aire | 30m/s |
Precisión Máxima de la Velocidad del Aire | ±3% + 0.8 km/h |
Resolución de la Velocidad del Aire | 0.4 → 30m/s |
Tipo de Sonda | Paleta |
Temperatura Máxima | +60°C |
Precisión Máxima de Medición de Temperatura | ±2 °C |
Potencia de la Fuente | Batería |
Tipo de Batería | 9 V |
Duración de Batería | 120 h |
Dimensiones | 275 x 65 x 45mm |
Peso | 284g |
Para usar con | Troubleshooting HVAC/R ducting systems |
Altura | 45mm |
Longitud | 275mm |
Anchura | 65mm |
Temperatura Mínima de Funcionamiento | 0°C |
Temperatura Máxima de Funcionamiento | +50°C |
Enlaces relacionados
- Anemómetro Kestrel KESTREL 3000, varios parámetros de medición
- Anemómetro Testo 405i Temperatura
- Anemómetro RS PRO AM-4204, medición de Velocidad del aire
- Anemómetro Kestrel KESTREL 1000, medición de Velocidad del aire
- Anemómetro Testo 410i Temperatura
- Anemómetro RS PRO AVM-01, medición de Velocidad del aire
- Anemómetro Testo 417, medición de Flujo de aire de Volumen
- Anemómetro Sefram SEFRAM9862, medición de Caudal de aire